11 kV - Class Pad Mounted Transformer Evironmental Friendly Energy Saving

Basic Information
Place of Origin: China
Brand Name: Pearl Electric
Certification: KEMA, CE, CCC, ISO9001
Model Number: PEO-S, S9~13
Minimum Order Quantity: 1 unit
Price: USD/RMB
Packaging Details: Seaworthy wooden packing
Delivery Time: 35~50days ex-work
Payment Terms: T/T, L/C
Supply Ability: 4000 units per year
Contact Now

 

Wind Power Farm , 11 kV - Class , Pad Mounted Transformer, Evironmental Friendly

 

 

1 General Descriptions

 

Specifications:
Rated H.V.: 11 kV, ±2×2.5%
Vector Group Dyn11/Yyn0/Yzn11
Rated L.V.: 0.4kV
Capacity: 30~2500
No-load Loss: 130~3200kW
Load Loss 600~20200kW
No-load Current: 2.1~0.5%
Impedance Voltage: 4/4.5/5.5%
Tap-changing On-load Tap-changing
Reference Standards IEC60076
Notes: The above specifications may be customized according to customer's requirement.


Functions and Advantages:


1. High safety protection

2. Complete functions and reliable performance

3. Flexible structure

4.Convenient maintenance

5. Low power consumption and energy saving

6. Low-noise

7. High protection level and weathering resistance

8. High mechanical strength and leakage-free


 

 

Equipment Fastening


With reference to the anchor bolt, place the equipment on the base, and then put flat gasket
and spring gasket on the anchor bolt. Finally screw the nut into the bolt.
Fix the cables into the cable rack and tighten the cables. The cable length set aside out of the
rack should be determined by the position of the rack, thus to ensure the elbow plug could be
placed into the bushings and reduce the stress applied on the cable. The cable length set aside
could also be adjusted later after the equipment installation is finished.

 

Recommendations:
To ensure the safety of the fastening components, the nut screwed onto the anchor could be
processed (for example rounding the edges of the nuts) to avoid unexpected dismounting.

 

Earthing


Before any system connection, please be sure the transformer is properly earthed.
The main earthing terminal of the equipment is located in the HV chamber and it must be
connected to the earthing rod fixed on the base.

 

Notice:
The total earthing terminal should not be welded on the outside of enclosure, for exposed
earthing terminal is easy to rust, which may cause improper system earthing. And also, welding
may also damage the coatings of the enclosure, which may cause rust on the enclosure.

 

 