Oil Immersed Prefabricated Substations Transformer 6.6 KV - Class Steel Housing Step Up and Down

Basic Information
Place of Origin: China
Brand Name: Pearl Electric
Certification: KEMA, CE, CCC, ISO9001
Model Number: PEO-S, S9~13
Minimum Order Quantity: 1 unit
Price: USD/RMB
Packaging Details: Seaworthy wooden packing
Delivery Time: 35~50days ex-work
Payment Terms: T/T, L/C
Supply Ability: 8000 units per year
Contact Now

 

 

6.6 kV - Class , Steel Housing , Seaworthy Packing , Container Substation , Oil Immersed Transformer

 

 

Introduction

 

1 Features

  1. High safety performance
  2. Functional maturation & Reliable performance
  3. Rich structure
  4. Convenient maintenance
  5. Low noise
  6. Wonderful weather resistance
  7. No-leakage

2 Applied Standards

  IEC 60076

 

Specifications:
Rated H.V.: 10 (10.5, 11, 6.3, 6) kV, ±2×2.5%
Vector Group Dyn11/Yyn0
Rated L.V.: 0.4/0.433 kV
Capacity: 50~4000
No-load Loss: 0.13~3.20kW
Load Loss 0.60~21.5kW
No-load Current: 0.6~2.3%
Impedance Voltage: 4/4.5/5.5%
Tap-changing On-load / Off-load Tap-changing
Cooling Method: ONAN/ONAF
Reference Standards IEC60076
Notes: The above specifications may be customized according to customer's requirement.
Features & Advantages
1. Low loss, low noise and high reliability.
2. Excellent dynamic thermal stability and high over-load capacity.
3. Simulation analysis was carried out for the core mould design, thus to greatly reduce noise level. Simulated lightning impulse wave process was carried out for HV winding mould design, thus to greatly improve product's anti-lightning impulse capability.
 

 

Maintenance

 

To maintain the equipment, user can open the chamber doors or dismantle the front panel. If the main sub-assembly needs to be repaired or replaced, take off product’s top cover and then lift the cover with lifting facility. Then lift the transformer or other switchgear for repairing or maintenance. In these cases, please contact the manufacturer for technical support.

Warning: Please refer to the respective manuals for items not described in this manual, or refer to the Preventive Test Regulation for Electric Power. Equipments on how to inspect these items.

Warning: If any other abnormality is found and not described within this manual, or the customer has no corresponding capability to deal with the problem, please contact the manufacturer in time.

No. Item Interval Contents Description
1 Lock When necessary The locking is not effective. Repair or replace the lock.
2 Enclosure sealing When necessary There are rain leaking in from the door or top cover. Replace the sealing tape or apply glass glue.
The enclosure is obviously damaged or rusted. Paint the surface.

 