Home ProductsDry Type Transformer

22kV - 1600kVA Dry Type Transformer , Explosion - Proof Dry Type Power Transformer

Certification
Good quality Oil Immersed Transformer for sales
Good quality Oil Immersed Transformer for sales
Customer Reviews
Pearl Electric is equipped with a professional ,efficient team.

—— CEO Mr.Leong

Nice peopele, nice product.

—— General Manger Morne

Pearl Electric is one of the leading supplier in China Nuclear project.

—— China Nuclear Power

Thanks for providing stable performance , high quality power equippment all the time. It is a AAAA level of qualified suppliers

—— China Guangdong Nuclear Power

Pearl Electric is a promissing high-tech enterprise.

—— State Power Investment

I'm Online Chat Now

22kV - 1600kVA Dry Type Transformer , Explosion - Proof Dry Type Power Transformer

China 22kV - 1600kVA Dry Type Transformer , Explosion - Proof Dry Type Power Transformer supplier

Large Image :  22kV - 1600kVA Dry Type Transformer , Explosion - Proof Dry Type Power Transformer

Product Details:

Place of Origin: China
Brand Name: Pearl Electric Co.,Ltd.
Certification: KEMA, CE, CCC, ISO9001
Model Number: PEC-S, SC(B) 9-15

Payment & Shipping Terms:

Minimum Order Quantity: 1 unit
Price: USD/RMB
Packaging Details: Seaworthy wooden packing
Delivery Time: 30days-50days ex-work
Payment Terms: T/T, L/C
Supply Ability: 9000 units per year
Contact Now
Detailed Product Description
Cooling: AN Or Customized Capacity: 1600KVA Or Customized
Rated H. V.: 22Kv Or Customized Rated L. V.: 0.433kv Or Customized
Impedance: 6% Or Customized Insulation Level: H. V.: Li/AC 75/28 L. V.: 0/3

 22kV - 1600kVA Cast Resin Dry Type Transformer, Three Phases, Two Winding, Power Distribution
 
Introduction

 

With the increasing need of oversea market, we developed PEC-S- series dry-type transformer whose winding is sealed up with epoxy enable the  dry-type transformer to be flame-retardant, explosion-proof, free from maintenance and pollution.  And overal dimension of Pearl Electric's cast resin dry type transformer is compacted and easy to install and delivery.

 

 

Features

 

  • Low loss, compact and light weight,
  • Low noise level,clamp-proof,anti-fouling,high mechanical strength,
  • Flame resisting, strong overload ability and low partial discharge quality,
  • Application to power transmission and distribution system,hotel,restaurant,commercial building,stadiums,chemical plants,stations,aiports,offshore drilling platforms,especially to heavy load centers and places with special fire protection requirements.


MAINTENANCE

 

Regular inspections and maintenance on a transformer are important to ensure that the transformer functions properly.

 

1 Generally, if the service site is clean and dry, check the transformer annually; if the site is dusty or exposed to chemicals or fog, inspections should be made every three to six months.

 

2 To guarantee adequate ventilation and prevent deterioration of the winding insulation, accumulated dust must be removed from the insulators, and upper and lower parts of windings. Use dry and compressed air (2~5 atmosphere pressure) to blow off dust from air channels.

 

3 Check to see whether attached parts and connections are secure; whether conductors and other accessories have become rusted or corroded; or whether electric creeping or carbonization appears on insulation. If any problem is found take appropriate corrective action.

 

4 After several years of operation (maximum of five years is recommended), check the transformer by testing insulation resistance according to section 9.4 and 9.5. Normally no other tests are required.

 

 
 

No. Items Unit  
I Basic Information       
1 Rated Voltage ratio kV 22kV / 0.433 kV
1.01 Rated Capacity kVA 1250
1.02 Applicable Standards   IEC 60076
1.03 Manufacturer   Pearl Electric
1.04 Country of Origin   China
II Electric Performance       
2.01 Rated Power kVA 1500
2.02 HV kV 22
2.03 LV kV 0.433
2.04 Frequency Hz 50
2.05 Number of phase   Three
2.06 Insullation Class   Class H
2.07 Temperature Rise (@40℃ ambient temperature) K 125K
2.08 Cooling Method   AN
2.09 Tapping Ranging   ±2*2.5%
2.1 Vector Group   Dyn11
2.11 Noise level dB 55
2.12 Impedance % 6
2.13 No-load loss W 2790
2.14 Load Loss (@120℃) W 13870
2.15 Local Partial discharge pC <10PC
2.16 Impulse Withstand Voltage (HV/LV) kV 75/0
2.17 Power Frequency Withstand Voltage
(HV/LV)
kV 28/3
2.18 Rated Duration of Short Circuit s 2
III Materials & Accessories       
3.01 Core Materials   Silicon Steel Sheet
3.02 Winding Materials   Copper conductor/foil
3.03 Insulation methods   HV vacuum cast / LV impregnant
3.04 Main Insulation Materials   Epoxy Resin

 
 
2 Applied Standard
GB/T10228 , GB1094.11 , IEC60076-11 , DIN42523
 
 