22 Kv 5 Mva 3 Phase Transformer / Oil Type Transformer With Oil Level Indicator

Basic Information
Place of Origin: China
Brand Name: Pearl Electric
Certification: IEC60076-11 ISO9001 ISO14001 KEMA CE
Model Number: PEO11-M-100/10
Minimum Order Quantity: negotiation
Price: negotiation
Packaging Details: Wooden Package, suitable for 20'/40' container
Delivery Time: 30-45days
Payment Terms: L/C, D/A, D/P, T/T, MoneyGram, Western Union
Contact Now

22 Kv 5 Mva 3 Phase Transformer / Oil Type Transformer With Oil Level Indicator

 

3 Phase Transformer Description

 

Power transformer three phase oil immsered electrical transformer rated voltage during 6-35kV, oil immersed transformer are most used in power plant,power grid transmission and distribution station,industry& commerce electrical substation as the electrical equipment of power transmission,

1, Two windings or three windings

2, On-load or no-load voltage tapping changer

3, Natural cooling or force air or oil cooling,

4, capacity range 10-5000kVA

 

3 Phase Transformer classification

 

Transformers can be divided into power transformers, test transformers, instrument transformers and special transformers for their purposes:

Power transformers are necessary equipment for power transmission and distribution and power user distribution;

Test equipment for carrying out pressure (boost) tests on electrical equipment;

The instrument transformer is used for electrical measurement and relay protection of the power distribution system (PT, CT);

 

Main components of 3 Phase Transformer

 

Moisture absorber (silicone tube)

Oil level gauge

Oil pillow

Explosion-proof tube

Signal thermometer

Tap changer

Gas signal relay (gas relay)

 

3 Phase Transformer specification.

 

S11-M-10kv                                
Type Rated capacity rated voltage Vector Group Po Pk Io Uk overall Dimension Weight L.V terminal
H.V L.V T L B H Total Oil Body
(kva) (kv) (kw) (kw) (%) (%) (mm) kg
PEO-M-30/10 30 6 0.4 Dyn11/
Yyn0
0.10 0.63/0.6 1.5 4 400 700 530 865 260 55 155 a
PEO-M-50/10 50 0.13 0.91/0.87 1.3 400 750 550 880 338 65 217 a
PEO-M-63/10 63 0.15 1.09/1.04 1.2 400 775 750 880 432 75 255 a
PEO-M-80/10 80 0.18 1.31/1.25 1.2 400 795 840 920 480 84 302 a
PEO-M-100/10 100 0.20 1.58/1.5 1.1 550 820 810 950 540 100 340 a
PEO-M-125/10 125 0.24 1.89/1.8 1.1 550 820 730 975 600 105 385 a
PEO-M-160/10 160 6.3 0.28 2.31/2.2 1 550 870 805 1025 695 117 465 a
PEO-M-200/10 200 0.34 2.73/2.6 1 550 880 860 1055 600 128 540 a
PEO-M-250/10 250 10 0.40 3.2/3.05 0.9 550 910 930 1110 900 145 595 b
PEO-M-315/10 315 0.48 3.83/3.65 0.9 660 1275 880 1110 1135 175 770 c
PEO-M-400/10 400 10.5 0.57 4.52/4.3 0.8 660 1445 1035 1140 1380 215 880 c
PEO-M-500/10 500 0.68 5.41/5.15 0.8 660 1555 1120 1110 1460 245 945 d
PEO-M-630/10 630 11 0.81 6.2 0.6 4.5 660 1590 1140 1140 1650 265 1090 d
PEO-M-800/10 800 0.98 7.5 0.6 660 1520 1150 1355 2220 345 1275 d
PEO-M-1000/10 1000 1.15 10.3 0.6 820 1660 1275 1285 2490 390 1395 e
PEO-M-1250/10 1250 1.36 12 0.5 820 1750 1275 1385 3150 525 1670 e

 

1.For tansformer of 500KVA or above, the load loss above slash is for Dyn11 connection, and value below for Yyn0 connection.
2. The tapping rang at H.V. winding is +/-2*2.5%.
3. Dimensions and weight are for reference only.