2500kva Oil Immersed Type Transformer , Low Noise Oil Cooled Transformers

Basic Information
Place of Origin: China
Brand Name: Pearl Electric
Certification: IEC60076-11 ISO9001 ISO14001 KEMA CE
Model Number: PEO11-M-100/10
Minimum Order Quantity: negotiation
Price: negotiation
Packaging Details: Wooden Package, suitable for 20'/40' container
Delivery Time: 30-45days
Payment Terms: L/C, D/A, D/P, T/T, MoneyGram, Western Union
Contact Now

2500kva Oil Immersed Type Transformer , Low Noise Oil Cooled Transformers​

 

Oil Immersed Type Transformer Description

 

This kind of product is applied to power system of three-phase, 50Hz as well as 35kV and below, it is the main transformer equipment of medium and small-sized transformer substation, supplies power distribution, power and illumination for the industry and agriculture.
The company introduces in domestic and overseas advanced technique, adopts the latest material and optimizes design, which enables the product structure more reasonable, and greatly improves the product electric strength, mechanical strength and heat-sinking capability. S9 series product has passed the short-circuit test prepared by Wuhan High Voltage Research Institute and also the test prepared by National Center for Quality Supervision & Test of Transformer.

 

Oil Immersed Type Transformer classification

 

Transformers can be divided into power transformers, test transformers, instrument transformers and special transformers for their purposes:

Power transformers are necessary equipment for power transmission and distribution and power user distribution;

Test equipment for carrying out pressure (boost) tests on electrical equipment;

The instrument transformer is used for electrical measurement and relay protection of the power distribution system (PT, CT);

 

Oil Immersed Type Transformer specification.

 

S11-M-10kv                                
Type Rated capacity rated voltage Vector Group Po Pk Io Uk overall Dimension Weight L.V terminal
H.V L.V T L B H Total Oil Body
(kva) (kv) (kw) (kw) (%) (%) (mm) kg
PEO-M-30/10 30 6 0.4 Dyn11/
Yyn0
0.10 0.63/0.6 1.5 4 400 700 530 865 260 55 155 a
PEO-M-50/10 50 0.13 0.91/0.87 1.3 400 750 550 880 338 65 217 a
PEO-M-63/10 63 0.15 1.09/1.04 1.2 400 775 750 880 432 75 255 a
PEO-M-80/10 80 0.18 1.31/1.25 1.2 400 795 840 920 480 84 302 a
PEO-M-100/10 100 0.20 1.58/1.5 1.1 550 820 810 950 540 100 340 a
PEO-M-125/10 125 0.24 1.89/1.8 1.1 550 820 730 975 600 105 385 a
PEO-M-160/10 160 6.3 0.28 2.31/2.2 1 550 870 805 1025 695 117 465 a
PEO-M-200/10 200 0.34 2.73/2.6 1 550 880 860 1055 600 128 540 a
PEO-M-250/10 250 10 0.40 3.2/3.05 0.9 550 910 930 1110 900 145 595 b
PEO-M-315/10 315 0.48 3.83/3.65 0.9 660 1275 880 1110 1135 175 770 c
PEO-M-400/10 400 10.5 0.57 4.52/4.3 0.8 660 1445 1035 1140 1380 215 880 c
PEO-M-500/10 500 0.68 5.41/5.15 0.8 660 1555 1120 1110 1460 245 945 d
PEO-M-630/10 630 11 0.81 6.2 0.6 4.5 660 1590 1140 1140 1650 265 1090 d
PEO-M-1250/10 1250 1.36 12 0.5 820 1750 1275 1385 3150 525 1670 e
PEO-M-1600/10 1600 1.64 14.5 0.5 820 1840 1345 1455 3640 605 2095 e
PEO-M-2000/10 2000 1.94 18.3 0.4 5.5 820 1945 1785 1675 4520 825 2435 e
PEO-M-2500/10 2500 2.29 21.2 0.5 820 1920 1770 1805 5190 850 2890 f

 

1.For tansformer of 500KVA or above, the load loss above slash is for Dyn11 connection, and value below for Yyn0 connection.
2. The tapping rang at H.V. winding is +/-2*2.5%.
3. Dimensions and weight are for reference only.

 

 

 

Contact Details
Sandy

Phone Number : 86-020-22626603

WhatsApp : +008618826241798