Duplex Winding Oil Immersed Transformer Base On IEC60076 Standard​

 

Oil Immersed Transformer Description

 

Oil Immersed Transformer is a device which USES the principle of electromagnetic induction to change ac voltage. The main components are primary coil, secondary coil and iron core.Main functions: voltage conversion, current conversion, impedance conversion, isolation, voltage stabilization, etc.

 

Copper foil winding technology is used for high current sections to achieve following advantages:

 

Sustaining short circuit forces without any distortion in low voltage and high current winding

Hot spot in LV windings regulated

No transposition, stray losses are minimal. Thus total copper losses are also further reduced

Total copper losses reduced vis-a-vis standard losses. Thus heat dissipating area also reduce

 

Main components of Oil Immersed Type Transformer

 

Oil pillow

Explosion-proof tube

Signal thermometer

Tap changer

Gas signal relay (gas relay)

 

Oil Immersed Transformer maintenance

 

Check the temperature and sound of the transformer for normality, and whether there are odors, discoloration, overheating and smoke.

Keep the surface of the porcelain bottle, casing and magnetic surface clean and observe whether there is crack damage or discharge.

The oil level of the oil-immersed transformer should be in accordance with the standard, the color is normal, and there is no oil leakage.

Whether the junction of the transformer high, low voltage and grounding is in good contact and there is no discoloration.

 

Oil Immersed Transformer specification.

 

S11-M-10kv                                
Type Rated capacity rated voltage Vector Group Po Pk Io Uk overall Dimension Weight L.V terminal
H.V L.V T L B H Total Oil Body
(kva) (kv) (kw) (kw) (%) (%) (mm) kg
PEO-M-80/10 80 6 0.4 Dyn11/
Yyn0
0.18 1.31/1.25 1.2 4 400 795 840 920 480 84 302 a
PEO-M-100/10 100 0.20 1.58/1.5 1.1 550 820 810 950 540 100 340 a
PEO-M-125/10 125 0.24 1.89/1.8 1.1 550 820 730 975 600 105 385 a
PEO-M-160/10 160 6.3 0.28 2.31/2.2 1 550 870 805 1025 695 117 465 a
PEO-M-200/10 200 0.34 2.73/2.6 1 550 880 860 1055 600 128 540 a
PEO-M-250/10 250 10 0.40 3.2/3.05 0.9 550 910 930 1110 900 145 595 b
PEO-M-315/10 315 0.48 3.83/3.65 0.9 660 1275 880 1110 1135 175 770 c
PEO-M-400/10 400 10.5 0.57 4.52/4.3 0.8 660 1445 1035 1140 1380 215 880 c
PEO-M-500/10 500 0.68 5.41/5.15 0.8 660 1555 1120 1110 1460 245 945 d
PEO-M-630/10 630 11 0.81 6.2 0.6 4.5 660 1590 1140 1140 1650 265 1090 d
PEO-M-800/10 800 0.98 7.5 0.6 660 1520 1150 1355 2220 345 1275 d
PEO-M-1000/10 1000 1.15 10.3 0.6 820 1660 1275 1285 2490 390 1395 e
PEO-M-1250/10 1250 1.36 12 0.5 820 1750 1275 1385 3150 525 1670 e
PEO-M-1600/10 1600 1.64 14.5 0.5 820 1840 1345 1455 3640 605 2095 e
PEO-M-2000/10 2000 1.94 18.3 0.4 5.5 820 1945 1785 1675 4520 825 2435 e
PEO-M-2500/10 2500 2.29 21.2 0.5 820 1920 1770 1805 5190 850 2890 f

 

1.For tansformer of 500KVA or above, the load loss above slash is for Dyn11 connection, and value below for Yyn0 connection.
2. The tapping rang at H.V. winding is +/-2*2.5%.