Fine Appearance Oil Immersed Transformer With Conservator ONAN/ONAF Cooling

Basic Information
Place of Origin: China
Brand Name: Pearl Electric
Certification: IEC60076-11 ISO9001 ISO14001 KEMA CE
Model Number: PEO11-M-100/10
Minimum Order Quantity: negotiation
Price: negotiation
Packaging Details: Wooden Package, suitable for 20'/40' container
Delivery Time: 30-45days
Payment Terms: L/C, D/A, D/P, T/T, MoneyGram, Western Union
Contact Now

Fine Appearance Oil Immersed Transformer with Conservator ONAN/ONAF Cooling

 

Oil Immersed Transformer  Specification


1. IEC ISO

2. Oil Immersed Transformer
3. Low noise&environmental protection

4. Low no-load loss&energy conservation

 

Oil Immersed Transformer Description

 

We offer Oil Immersed Power and Distribution Transformers. Distribution transformers for industrial application is available with primary voltages of up to 33 KV and secondary voltages ranging from 433 to 11000 V. The capacity range is up to 5000 KVA. We manufacture single phase distribution transformers, three phase distribution transformers and industrial distribution transformers.

These single phase distribution transformers and three phase distribution transformers are available with ''Tap Changer'' options as well as "Off Circuit Manually Operated" and "On Load Tap Changer" (OLTC) with AVR and RTCC panel.

 

Copper foil winding technology is used for high current sections to achieve following advantages:

 

Sustaining short circuit forces without any distortion in low voltage and high current winding

Hot spot in LV windings regulated

No transposition, stray losses are minimal. Thus total copper losses are also further reduced

Total copper losses reduced vis-a-vis standard losses. Thus heat dissipating area also reduce

 

Main components of Oil Immersed Type Transformer

Moisture absorber (silicone tube)

Oil level gauge

Oil pillow

Explosion-proof tube

Signal thermometer

Tap changer

Gas signal relay (gas relay)

 

 

Oil Immersed Type Transformer specification.

 

S11-M-10kv                                
Type Rated capacity rated voltage Vector Group Po Pk Io Uk overall Dimension Weight L.V terminal
H.V L.V T L B H Total Oil Body
(kva) (kv) (kw) (kw) (%) (%) (mm) kg
PEO-M-30/10 30 6 0.4 Dyn11/
Yyn0
0.10 0.63/0.6 1.5 4 400 700 530 865 260 55 155 a
PEO-M-50/10 50 0.13 0.91/0.87 1.3 400 750 550 880 338 65 217 a
PEO-M-63/10 63 0.15 1.09/1.04 1.2 400 775 750 880 432 75 255 a
PEO-M-80/10 80 0.18 1.31/1.25 1.2 400 795 840 920 480 84 302 a
PEO-M-100/10 100 0.20 1.58/1.5 1.1 550 820 810 950 540 100 340 a
PEO-M-125/10 125 0.24 1.89/1.8 1.1 550 820 730 975 600 105 385 a
PEO-M-400/10 400 10.5 0.57 4.52/4.3 0.8 660 1445 1035 1140 1380 215 880 c
PEO-M-500/10 500 0.68 5.41/5.15 0.8 660 1555 1120 1110 1460 245 945 d
PEO-M-630/10 630 11 0.81 6.2 0.6 4.5 660 1590 1140 1140 1650 265 1090 d
PEO-M-800/10 800 0.98 7.5 0.6 660 1520 1150 1355 2220 345 1275 d
PEO-M-1000/10 1000 1.15 10.3 0.6 820 1660 1275 1285 2490 390 1395 e
PEO-M-1250/10 1250 1.36 12 0.5 820 1750 1275 1385 3150 525 1670 e
PEO-M-1600/10 1600 1.64 14.5 0.5 820 1840 1345 1455 3640 605 2095 e
PEO-M-2000/10 2000 1.94 18.3 0.4 5.5 820 1945 1785 1675 4520 825 2435 e
PEO-M-2500/10 2500 2.29 21.2 0.5 820 1920 1770 1805 5190 850 2890 f

 

1.For tansformer of 500KVA or above, the load loss above slash is for Dyn11 connection, and value below for Yyn0 connection.
2. The tapping rang at H.V. winding is +/-2*2.5%.
3. Dimensions and weight are for reference only.

 

 

 

Contact Details
Sandy

Phone Number : 86-020-22626603

WhatsApp : 008618826241798