Industrial Three Phase Oil Immersed Transformer With ONAN Cooling Type

Basic Information
Place of Origin: China
Brand Name: Pearl Electric
Certification: IEC60076-11 ISO9001 ISO14001 KEMA CE
Model Number: PEO11-M-100/10
Minimum Order Quantity: negotiation
Price: negotiation
Packaging Details: Wooden Package, suitable for 20'/40' container
Delivery Time: 30-45days
Payment Terms: L/C, D/A, D/P, T/T, MoneyGram, Western Union
Contact Now

Industrial Three Phase Oil Immersed Transformer With ONAN Cooling Type

 

Oil Immersed Transformer Introduction

 

Three phase oil immersed transformer is different from the general oil immersed transformer. It cancels the oil storage tank and uses the corrugated plate heat sink of the oil storage tank to radiating & cooling, which to compensate the increase or decrease of oil volume by its elastic expansion and contraction.

 

Oil Immersed Transformer application 

 

All series of transformer are suitable for 10kV, 20kV and 35kV power transmission and distribution systems, and can be used for power and lighting in residential areas, commercial streets, industrial and mining enterprises and rural areas.

 

 

 

 

Oil Immersed Transformer  specification.

 

S11-M-10kv                                
Type Rated capacity rated voltage Vector Group Po Pk Io Uk overall Dimension Weight L.V terminal
H.V L.V T L B H Total Oil Body
(kva) (kv) (kw) (kw) (%) (%) (mm) kg
PEO-M-30/10 30 6 0.4 Dyn11/
Yyn0
0.10 0.63/0.6 1.5 4 400 700 530 865 260 55 155 a
PEO-M-50/10 50 0.13 0.91/0.87 1.3 400 750 550 880 338 65 217 a
PEO-M-63/10 63 0.15 1.09/1.04 1.2 400 775 750 880 432 75 255 a
PEO-M-80/10 80 0.18 1.31/1.25 1.2 400 795 840 920 480 84 302 a
PEO-M-315/10 315 10 0.48 3.83/3.65 0.9 660 1275 880 1110 1135 175 770 c
PEO-M-400/10 400 10.5 0.57 4.52/4.3 0.8 660 1445 1035 1140 1380 215 880 c
PEO-M-500/10 500 0.68 5.41/5.15 0.8 660 1555 1120 1110 1460 245 945 d
PEO-M-630/10 630 11 0.81 6.2 0.6 4.5 660 1590 1140 1140 1650 265 1090 d
PEO-M-800/10 800 0.98 7.5 0.6 660 1520 1150 1355 2220 345 1275 d
PEO-M-1000/10 1000 1.15 10.3 0.6 820 1660 1275 1285 2490 390 1395 e
PEO-M-1250/10 1250 1.36 12 0.5 820 1750 1275 1385 3150 525 1670 e
PEO-M-1600/10 1600 1.64 14.5 0.5 820 1840 1345 1455 3640 605 2095 e
PEO-M-2000/10 2000 1.94 18.3 0.4 5.5 820 1945 1785 1675 4520 825 2435 e
PEO-M-2500/10 2500 2.29 21.2 0.5 820 1920 1770 1805 5190 850 2890 f

 

1.For tansformer of 500KVA or above, the load loss above slash is for Dyn11 connection, and value below for Yyn0 connection.
2. The tapping rang at H.V. winding is +/-2*2.5%.
3. Dimensions and weight are for reference only.

 

 

 

 

 

 