10kV - Class Pad Mounted Transformer Wind Power

Basic Information
Place of Origin: China
Brand Name: Pearl Electric Co.,Ltd.
Certification: KEMA, CE, CCC, ISO9001
Model Number: PEO-S, S9~13
Minimum Order Quantity: 1 unit
Price: USD/RMB
Packaging Details: Seaworthy wooden packing
Delivery Time: 35~50days ex-work
Payment Terms: T/T, L/C
Supply Ability: 4000 units per year
Contact Now

 

 

10kV - Class , Pad Mounted , Substation Transformer for New Energy , Oil - Immersed Transformer , Wind Power Farm

 

 

Pad-mounted Transformer Introduction


The pad-mounted transformer manufactured by Pearl is the latest product developed on the basis of absorbing the most advanced technology and advantages of the similar products while considering customer's special practical operation habits. It features low loss, small size, easy installation and maintenance and low engineering cost. It can be installed both indoor and outdoor.

 

Specifications:
Rated H.V.: 10 (10.5, 11, 6.3, 6)kV, ±2×2.5%
Vector Group Dyn11/Yyn0/Yzn11
Rated L.V.: 0.4kV
Capacity: 30~2500
No-load Loss: 130~3200kW
Load Loss 600~20200kW
No-load Current: 2.1~0.5%
Impedance Voltage: 4/4.5/5.5%
Tap-changing On-load Tap-changing
Reference Standards IEC60076
Notes: The above specifications may be customized according to customer's requirement.


Service Conditions:


Ambient temperature:


Maximum: +40 centigrade degrees
Minimum: -25 centigrade degrees
Maximum average monthly temperature: +30 centigrade degrees
Relatively humidity: at 25 centigrade degrees
Daily average RH: not more than 95%
Monthly average RH: not more than 90%.

 

Altitude: ≤1000m


Shockproof:
≤3m/s2 horizontally
≤1.5m/s2 vertically

 

Installation Environment:
No obvious dirtiness, no explosive and corrosive gas or powder. The installation site should have good air ventilation and no furious vibration and shocking forces.


Functions and Advantages:


1. High safety protection

2. Complete functions and reliable performance

3. Flexible structure

4.Convenient maintenance

5. Low power consumption and energy saving

6. Low-noise

7. High protection level and weathering resistance

8. High mechanical strength and leakage-free


 

 

Tertiary terminals

 

Tertiary winding terminals shall be on the right-hand end of the transformer when viewed from the HV

side. 

 

Terminal markings

 

The terminal markings on the diagram plate shall be as specified in appendix D of BS 171.

Terminals shall be positioned as indicated in 

Terminal markings characters shall be in relief, adjacent to their appropriate terminals.

The characters may be of brass, steel or other acceptable metal and shall be permanently fixed to the tank by means of brazing or welding.

 

10kV - Class Pad Mounted Transformer Wind Power